@article{MTMT:34189383, title = {Firework smoke: Impacts on urban air quality and deposition in the human respiratory system}, url = {https://m2.mtmt.hu/api/publication/34189383}, author = {Salma, Imre and Farkas, Árpád and Weidinger, Tamás and Balogh, Miklós}, doi = {10.1016/j.envpol.2023.121612}, journal-iso = {ENVIRON POLLUT}, journal = {ENVIRONMENTAL POLLUTION}, volume = {328}, unique-id = {34189383}, issn = {0269-7491}, abstract = {Particle number concentrations and size distributions resulting from the firework displays held in Budapest, Hungary every year on St. Stephen's Day were studied over a period of seven years. In the year most impacted, the total particle number concentration reached its peak measured level of 369 x 103 cm-3 5 min after the end of the display, and returned to the pre-event state within 45 min. The fireworks increased hourly mean concentrations by a factor of 5-6, whereas the concentrations in the diameter range of 100-1000 nm, in which the magnitude of the increase was the greatest, were elevated by a factor of 20-25. An extra particle size mode at 203 nm was manifested in the size distributions as result of the fireworks. The PM10 mass concentrations at peak firework influence and as 1-h mean increased 123 and 58 times, respectively, relative to the concentration before the display. The smoke was characterised by a relatively short overall atmospheric residence time of 25 min. Spatiotemporal dispersion simulations revealed that there were substantial vertical and horizontal concentration gradients in the firework plume. The affected area made up a large part of the city. Not only the spectators of the display at the venue and nearby areas, but the population located further away downwind of the displays and more distant, large and populous urban quarters were affected by the plume and its fallout. The fireworks increased the deposition rate in the respiratory system of females by a factor of 4, as a conservative estimate. The largest surface density deposition rates were seen in the segmental and sub-segmental bronchi, which represents an excessive risk to health. Compared to adults, children were more susceptible to exposure, with the maximum surface density deposition rates in their case being three times those of adults in the trachea.}, keywords = {GROWTH; particulate matter; air pollution; pollution; simulation; size distribution; NUCLEATION; SIZE DISTRIBUTIONS; particle number concentration; ULTRAFINE ATMOSPHERIC AEROSOL; Particle formation; Fireworks; fine particulate; Plume dispersion}, year = {2023}, eissn = {1873-6424}, orcid-numbers = {Salma, Imre/0000-0001-8319-1647; Weidinger, Tamás/0000-0001-7500-6579} } @article{MTMT:34084196, title = {A tűzijáték árnyai és fényei}, url = {https://m2.mtmt.hu/api/publication/34084196}, author = {Salma, Imre and Farkas, Árpád and Weidinger, Tamás and Balogh, Miklós}, journal-iso = {MAGY KEM LAP}, journal = {MAGYAR KÉMIKUSOK LAPJA}, volume = {78}, unique-id = {34084196}, issn = {0025-0163}, year = {2023}, eissn = {1588-1199}, pages = {214-217}, orcid-numbers = {Salma, Imre/0000-0001-8319-1647; Weidinger, Tamás/0000-0001-7500-6579} } @article{MTMT:33681855, title = {Open photoacoustic cell for concentration measurements in rapidly flowing gas}, url = {https://m2.mtmt.hu/api/publication/33681855}, author = {Fekete, János and Torma, Péter and Szabó, Anna and Balogh, Miklós and Horváth, Csaba and Weidinger, Tamás and Szabó, Gábor and Bozóki, Zoltán}, doi = {10.1016/j.pacs.2023.100469}, journal-iso = {PHOTOACOUSTICS}, journal = {PHOTOACOUSTICS}, volume = {30}, unique-id = {33681855}, issn = {2213-5979}, abstract = {High temporal resolution concentration measurements in rapid gas flows pose a serious challenge for most analytical instruments. The interaction of such flows with solid surfaces can generate excessive aero-acoustic noise making the application of the photoacoustic detection method seemingly impossible. Yet, the fully open photoacoustic cell (OC) has proven to be operable even when the measured gas flows through it at a velocity of several m/s. The OC is a slightly modified version of a previously introduced OC based on the excitation of a combined acoustic mode of a cylindrical resonator. The noise characteristics and analytical performance of the OC are tested in an anechoic room and under field conditions. Here we present the first successful application of a sampling-free OC for water vapor flux measurements.}, year = {2023}, eissn = {2213-5979}, orcid-numbers = {Torma, Péter/0000-0001-9282-6931; Horváth, Csaba/0000-0002-5154-9760; Weidinger, Tamás/0000-0001-7500-6579; Szabó, Gábor/0000-0001-6756-4677} } @{MTMT:33120024, title = {Transient Wind Forcing: a method for modelling wind shear in building-scale Large Eddy Simulations}, url = {https://m2.mtmt.hu/api/publication/33120024}, author = {Koren, Márton and Balogh, Miklós and Kristóf, Gergely}, booktitle = {PHYSMOD 2022 - International Workshop on Physical Modeling of Flow and Dispersion Phenomena}, unique-id = {33120024}, year = {2022}, pages = {111-111}, orcid-numbers = {Kristóf, Gergely/0000-0001-7572-6875} } @CONFERENCE{MTMT:33119050, title = {Dispersion simulation of firework-related aerosols}, url = {https://m2.mtmt.hu/api/publication/33119050}, author = {Balogh, Miklós and Farkas, Árpád and Weidinger, Tamás and Salma, Imre}, booktitle = {CMFF’22 Workshop on " Coupling techniques in multiscale atmospheric models: Microphysics, local scale simulations, PBL structureels"}, unique-id = {33119050}, year = {2022}, orcid-numbers = {Weidinger, Tamás/0000-0001-7500-6579; Salma, Imre/0000-0001-8319-1647} } @inproceedings{MTMT:33119045, title = {AEROACOUSTIC NOISE REDUCTION OF OPEN PHOTOACOUSTIC CELLS SUPPORTED BY EXPERIMENTS AND SIMULATIONS}, url = {https://m2.mtmt.hu/api/publication/33119045}, author = {Balogh, Miklós and Koscsó, Gábor and Kocsis, Bálint and Horváth, Csaba and Bozóki, Zoltán}, booktitle = {Proceedings of Conference on Modelling Fluid Flow (CMFF'22)}, unique-id = {33119045}, year = {2022}, pages = {452-459}, orcid-numbers = {Horváth, Csaba/0000-0002-5154-9760} } @inproceedings{MTMT:32540235, title = {Légszárító patronok porózus közegében kialakuló áramlások szimulációja és modellezése nyílt forráskódú szoftverkörnyezetben}, url = {https://m2.mtmt.hu/api/publication/32540235}, author = {Balogh, Miklós and Zádeczki, Zalán}, booktitle = {VI. Gépészeti Szakmakultúra Konferencia}, unique-id = {32540235}, year = {2021} } @article{MTMT:31806292, title = {Measurement-driven Large Eddy Simulation of dispersion in street canyons of variable building height}, url = {https://m2.mtmt.hu/api/publication/31806292}, author = {Papp, Bálint and Kristóf, Gergely and Istók, Balázs and Koren, Márton and Balczó, Márton and Balogh, Miklós}, doi = {10.1016/j.jweia.2020.104495}, journal-iso = {J WIND ENG IND AEROD}, journal = {JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS}, volume = {211}, unique-id = {31806292}, issn = {0167-6105}, year = {2021}, eissn = {1872-8197}, orcid-numbers = {Papp, Bálint/0000-0001-8043-5271; Kristóf, Gergely/0000-0001-7572-6875; Istók, Balázs/0000-0002-0248-0074; Balczó, Márton/0000-0002-1273-3047} } @article{MTMT:31720604, title = {Kis léptékű nem-hidrosztatikus légköri áramlások numerikus modellezése mérnöki célokra}, url = {https://m2.mtmt.hu/api/publication/31720604}, author = {Koren, Márton and Balogh, Miklós}, journal-iso = {LÉGKÖR}, journal = {LÉGKÖR: AZ ORSZÁGOS METEOROLÓGIAI INTÉZET SZAKMAI TÁJÉKOZTATÓJA}, volume = {65}, unique-id = {31720604}, issn = {0133-3666}, year = {2020}, pages = {130-135} } @misc{MTMT:31318279, title = {Meteorological sensor placement considerations for a fixed-wing Unmanned Aircraft System. Előadás prezentáció}, url = {https://m2.mtmt.hu/api/publication/31318279}, author = {Vránics, Dávid Ferenc and Balogh, Miklós and GYÖNGYÖSI, András Zénó and Istenes, Zoltán and WEIDINGER, Tamás and MAKKAY, Imre and Bottyán, Zsolt and Palik, Mátyás}, unique-id = {31318279}, year = {2019}, pages = {1-29}, orcid-numbers = {Bottyán, Zsolt/0000-0003-0729-2774; Palik, Mátyás/0000-0002-2304-372X} }