TY - BOOK ED - Balázs, Péter Attila ED - Barneva, Reneta P. ED - Brimkov, Valentin E. ED - Nagy, Antal TI - Combinatorial Image Analysis. 23rd International Workshop, IWCIA 2025, Szeged, Hungary, September 24–26, 2025, Revised Selected Papers TS - 23rd International Workshop, IWCIA 2025, Szeged, Hungary, September 24–26, 2025, Revised Selected Papers T3 - Lecture Notes in Computer Science, ISSN 0302-9743 ; 15985. PB - Springer Nature Switzerland CY - Cham PY - 2026 SN - 9783032193476 DO - 10.1007/978-3-032-19347-6 UR - https://m2.mtmt.hu/api/publication/37082630 ID - 37082630 LA - English DB - MTMT ER - TY - JOUR AU - Lengyel, Laura AU - Laczi, Balázs AU - Nagy, Antal AU - Segatto, Emil AU - Balazs, Gergo AU - Sáfrány-Fárk, Árpád TI - Status report on novel intraoral scanner-based registration method of axes of rotation of the mandible. Proof of potential applicability and technological glass ceiling of in-house development TS - Proof of potential applicability and technological glass ceiling of in-house development JF - PLOS ONE J2 - PLOS ONE VL - 21 PY - 2026 IS - 2 PG - 20 SN - 1932-6203 DO - 10.1371/journal.pone.0342893 UR - https://m2.mtmt.hu/api/publication/36974002 ID - 36974002 AB - A fast, equipment- and radiation-free input methodology for digital articulation is desirable for basic dental and surgical procedures of relatively low complexity. Our team previously proposed an intraoral scanner (IOS)-based strategy for calculating the mandibular axis of rotation using dual bite registrations in open and closed positions. In this study, we aimed to develop a methodology for validating this registration system using a state-of-the-art jaw motion tracking device (Modjaw). The bite alignment accuracy of the scanner used (Medit i600) proved sufficient for the task; however, its technical settings allow processing of only a limited number of bite positions, thereby restricting the number of cases that can be analysed. While in-house, insoluble technical limitations restricted the number of participants to four, significantly limiting the generalizability of the results, several main trends nevertheless appear to emerge: We verified our previous results regarding the error-induced effect ratios (EcD and AEcFE) and provided strong in-vivo support for our earlier in-vitro findings. Notably, alignment of axes obtained with our IOS-based method closely resembled the "parallel error direction" described previously. The reproducibility of our methodology approaches the desired 0.1 mm error threshold, but when compared with our control tool (Modjaw), it does not yet meet this criterion. The level of inaccuracy suggests that the goal remains achievable; with protocol modifications, the method could become an acceptable alternative for virtual articulation. Our findings highlight persistent clinical dilemmas and underline that many patient safety concerns remain unresolved, even in the era of advanced digital technologies. We proposed a renewed digital version of the conventional analogue control setup of articulation methods by dynamic motion registers, as a potential strategy to establish and maintain patient safety standards. Although integrating different digital platforms poses significant technological challenges, automated metrics and comparative setups offer advanced possibilities compared to the analogue experimental era. LA - English DB - MTMT ER - TY - CHAP AU - Balázs, Péter Attila AU - Reneta, P. Barneva AU - Valentin, E. Brimkov AU - Nagy, Antal ED - Balázs, Péter Attila ED - Barneva, Reneta P. ED - Brimkov, Valentin E. ED - Nagy, Antal TI - Preface T2 - Combinatorial Image Analysis PB - Springer Nature Switzerland CY - Cham SN - 9783032193476 T3 - Lecture Notes in Computer Science, ISSN 0302-9743 ; 15985. PY - 2026 PG - 2 UR - https://m2.mtmt.hu/api/publication/37326165 ID - 37326165 LA - English DB - MTMT ER - TY - JOUR AU - Laczi, Balázs AU - Nagy, Antal AU - Sáfrány-Fárk, Árpád TI - Instantaneous center of rotation, the first step to build up the digital laboratory of complex motions JF - PLOS ONE J2 - PLOS ONE VL - 20 PY - 2025 IS - 8 PG - 19 SN - 1932-6203 DO - 10.1371/journal.pone.0329021 UR - https://m2.mtmt.hu/api/publication/36284021 ID - 36284021 AB - Calculating instantaneous centers of rotation to describe combined rotational and translational motions has a long history in many fields of applied science and basic rigid body kinematics. However, only some theoretical studies have explored the fundamental characteristics of this system. This study used digital three-dimensional modeling and computing methods to examine the system's operation in a controlled in vitro-like environment. The effects of inaccurate registrations on the resulting motion were also analyzed. We registered 28.65, 14.33 and 9.55 EcD_ratios for 2°, 4° and 6° of closure respectively, and described a structured, predictable framework based on a solid mathematical background. Our findings align with previous publications, indicating that the longstanding debate over the pure rotation of the temporomandibular joint arises from misinterpretations of scientific findings due to a lack of fundamental knowledge of the basic characteristics of the system. Our simplified geometrical approach significantly reduces the complexity of the existing complex kinematic model, making it more accessible for practical applications, easier to understand, and potentially more applicable in orthopedics or temporomandibular joint radiology. We identified five fundamental characteristics of the system as we described the effects of the acting translational component in the complex motion. We also presented a detailed model concerning the effects of inaccurate rotation axis registration on the resulting compromised transformation, improving our understanding of the error tolerance level of articulation systems. Our results show that the system might tolerate errors as great as 3-4 cm in some settings in the parallel error direction, while in case of circular and perpendicular error types an approximately 2 mm axis registration error would exceed the clinically desirable 0.1 mm occlusal error level. Our experimental modeling strategy might provide extensive data for machine learning and for analyzing and comprehending the fundamental characteristics of different complex motion systems in the future. LA - English DB - MTMT ER - TY - JOUR AU - Sáfrány-Fárk, Árpád AU - Laczi, Balázs AU - Nagy, Antal AU - Lengyel, Laura AU - Piffkó, József AU - Segatto, Emil TI - A novel approach for determining instantaneous centers of rotation of the mandible with an intraoral scanner: A preliminary study JF - PLOS ONE J2 - PLOS ONE VL - 18 PY - 2023 IS - 5 PG - 15 SN - 1932-6203 DO - 10.1371/journal.pone.0285162 UR - https://m2.mtmt.hu/api/publication/33790411 ID - 33790411 N1 - Department of Oral and Maxillofacial Surgery, Albert Szent-Györgyi Medical School, University of Szeged, Szeged, Hungary Faculty of Science and Informatics, Department of Image Processing and Computer Graphics, Institute of Informatics, University of Szeged, Szeged, Hungary Export Date: 04 January 2024; Cited By: 0; Correspondence Address: A. Safrany-Fark; Department of Oral and Maxillofacial Surgery, Albert Szent-Györgyi Medical School, University of Szeged, Szeged, Hungary; email: safrany-fark.arpad@med.u-szeged.hu; CODEN: POLNC LA - English DB - MTMT ER - TY - JOUR AU - Olasz, Csaba AU - Varga, László AU - Nagy, Antal TI - Novel U-net based deep neural networks for transmission tomography JF - JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY J2 - J X-RAY SCI TECHNOL VL - 30 PY - 2022 IS - 1 SP - 13 EP - 31 PG - 19 SN - 0895-3996 DO - 10.3233/XST-210962 UR - https://m2.mtmt.hu/api/publication/32587579 ID - 32587579 LA - English DB - MTMT ER - TY - CHAP AU - Olasz, Csaba AU - Varga, László AU - Nagy, Antal TI - Beam hardening artifact removal by the fusion of FBP and deep neural networks T2 - Thirteenth International Conference on Digital Image Processing (ICDIP 2021) SN - 9781510646001 PY - 2021 SP - 73 DO - 10.1117/12.2601071 UR - https://m2.mtmt.hu/api/publication/32094208 ID - 32094208 LA - English DB - MTMT ER - TY - CONF AU - Olasz, Csaba AU - Varga, László AU - Nagy, Antal TI - Tomográfiai modellek interpolációs hibájának vizsgálata T2 - Képfeldolgozók és Alakfelismerők társaságának 13. konferenciája, KÉPAF 2021 PB - Képfeldolgozók és Alakfelismerők Társasága C1 - Budapest PY - 2021 UR - https://m2.mtmt.hu/api/publication/32589084 ID - 32589084 LA - Hungarian DB - MTMT ER - TY - CHAP AU - Olasz, Csaba AU - Varga, László AU - Nagy, Antal ED - Bebis, George ED - Boyle, Richard ED - Parvin, Bahram ED - Koracin, Darko ED - Ushizima, Daniela ED - Chai, Sek ED - Sueda, Shinjiro ED - Lin, Xin ED - Lu, Aidong ED - Thalmann, Daniel ED - Wang, Chaoli ED - Xu, Panpan TI - Evaluation of the Interpolation Errors of Tomographic Projection Models T2 - Advances in Visual Computing: 14th International Symposium on Visual Computing, ISVC 2019 : Proceedings, Part II PB - Springer Cham CY - Cham SN - 9783030337223 T3 - Lecture Notes in Computer Science, ISSN 0302-9743 ; 11845. PY - 2019 SP - 394 EP - 406 PG - 13 DO - 10.1007/978-3-030-33723-0_32 UR - https://m2.mtmt.hu/api/publication/30975593 ID - 30975593 LA - English DB - MTMT ER - TY - CHAP AU - Olasz, Csaba AU - Varga, László AU - Nagy, Antal ED - Hudoba, Péter TI - CT scanner calibration based on optimization T2 - 5th Winter School of PhD Students in Informatics and Mathematics PB - Doktoranduszok Országos Szövetsége (DOSZ) CY - Budapest SN - 9786155586231 PY - 2018 SP - 37 EP - 38 PG - 2 UR - https://m2.mtmt.hu/api/publication/30673155 ID - 30673155 LA - English DB - MTMT ER -