Changes in the mechanical properties of tibialis anterior and peroneus longus allograft depending on sterilization method and storage time

Faragó, D. ✉ [Faragó, Dénes (Biomechanika), szerző] Mechatronika, Optika és Gépészeti Informatika T... (BME / GPK); Karácsony, A. F. [Karácsony, Atilla (ortopédia, trauma...), szerző] Traumatológiai Klinika (SE / AOK / K); Orlovits, Z. [Orlovits, Zsanett (alkalmazott matem...), szerző] Mechatronika, Optika és Gépészeti Informatika T... (BME / GPK); Pap, K. [Pap, Károly (Ortopédia, trauma...), szerző] Traumatológiai Klinika (SE / AOK / K); Kiss, R. M. [Kiss, Rita (Biomechanika, Bio...), szerző] Mechatronika, Optika és Gépészeti Informatika T... (BME / GPK)

Angol nyelvű Szakcikk (Folyóiratcikk) Tudományos
Megjelent: BONE & JOINT RESEARCH 2046-3758 2046-3758 14 (3) pp. 270-280 2025
  • SJR Scopus - Orthopedics and Sports Medicine: D1
Támogatások:
  • (TKP-6-6/PALY-2021) Támogató: Kulturális és Innovációs Minisztérium Nemzeti Kutatási Fejlesztési és Innovációs Alap
  • (TKP-9-8/PALY-2021)
Szakterületek:
  • Traumatológia
Aims he aim of the present research was to analyze the effects of different sterilization methods and storage times on the mechanical properties (load at first break, strain at first break, maximum load, strain at maximum load, and Young's modulus of elasticity) of different allografts compared to native groups. Methods Two types of grafts were harvested from human cadavers: 165 tibialis anterior (TA) and 166 peroneus longus (PL) tendons. According to the two types of sterilization methods (gamma and electron beam irradiation) or the lack of one, and the six types of storage time (one to six months), 36 groups were created. In addition, we created a 1 to 1 native group, which was not sterilized and stored, tested within four hours of collection. Results In the results of tendon type TA compared to TA native group, we observed significant differences at the fifth month of storage for all measured parameters. Load at first break of the frozen values at the fifth month was significantly inferior to the native group (p = 0.034). For strain at first break and strain at maximum load, all sterilization methods were significantly inferior at the fifth month (p = 0.003 to p = 0.009). Maximum load values were significantly superior with E-beam irradiation at the fifth month (p = 0.003), and also significantly higher with gamma irradiation at the fifth month (p = 0.009). Young's modulus showed significantly inferior values in the frozen tendons at the fifth month (p = 0.001 to p = 0.003). In tendon type PL, no significant differences were found for any of the tested parameters compared to the native group. Conclusion Our results indicate that freezing alters mechanical properties via the decrease seen in the ultimate tensile strength. In addition, at the fifth and sixth months of storage, time could notably affect allografts rather than the sterilization procedures.
Hivatkozás stílusok: IEEEACMAPAChicagoHarvardCSLMásolásNyomtatás
2026-10-08 12:49