The effect of the combined application of solid- and gas-phase flame retardants in
epoxy gelcoats on the thermal stability, fire performance and adhesion of coated carbon
fibre–reinforced epoxy composites
We explored the combined effect of two flame retardants (FR) containing phosphorus—ammonium
polyphosphate (APP) and resorcinol bis(diphenyl phosphate) (RDP)—on the fire performance
of coated carbon fibre–reinforced composites. We prepared epoxy gelcoats with 10%
total phosphorus content with different ratios of APP and RDP and characterised by
DSC, TGA, rheometry, limiting oxygen index, UL-94 test and mass loss calorimetry (MLC).
The increasing ratio of liquid RDP led to a significant reduction in viscosity: gelcoats
over 3%P RDP content became sprayable without any diluents. The gelcoat with 7%P APP
and 3%P RDP had the best fire performance (pHRR of 141 kW m−2), followed by the gelcoat
with 6%P APP and 4%P RDP (pHRR of 171 kW m−2). We prepared flame-retarded and reference
epoxy/carbon fibre–reinforced composites by hand lamination, wet compression and vacuum
infusion. The flammability of the laminates decreased with increasing fibre content
due to the reduction in resin content; therefore, the vacuum-infused sample performed
the best. However, due to the more compact structure of the vacuum-infused sample,
the reduction in total heat release was greater than expected from the fibre content
alone. The MLC results of the coated composites indicated that it was not necessary
to incorporate 3%P RDP in the composite matrix of the coated composites, as FRs in
the coating alone are sufficient to protect the composite. The adhesion between the
composite and the gelcoat was influenced by the presence of the FR additives in the
resins, and adhesion was stronger when the composite matrix and the gelcoat contained
the same FR.