Back-calculation of keratometer index based on OCT data and raytracing – a Monte Carlo simulation
Langenbucher, A. ✉ [Langenbucher, Achim (Ophthalmology, op...), szerző]
;
Szentmáry, N. [Szentmáry, Nóra (Szemészet), szerző] Szemészeti Klinika (SE / AOK / K)
;
Weisensee, J.
;
Cayless, A.
;
Menapace, R.
;
Hoffmann, P.
Angol nyelvű Szakcikk (Folyóiratcikk) Tudományos
Megjelent:
ACTA OPHTHALMOLOGICA 1755-375X 1755-3768
99
(8)
pp. 843-849
2021
SJR Scopus - Medicine (miscellaneous): Q1
Azonosítók
MTMT: 31900248
DOI:
10.1111/aos.14794
WoS:
000617103000001
Scopus:
85100969546
PubMed:
33576147
Purpose: This study aims to develop a raytracing-based strategy for calculating corneal power from anterior segment optical coherence tomography data and extracting the individual keratometer index, which converts the corneal front surface radius to corneal power. Methods: A large OCT dataset (10,218 eyes of 8,430 patients) from the Casia 2 (Tomey, Japan) was post-processed in MATLAB (MathWorks, USA). Radius of curvature, asphericity of the corneal front and back surface, central corneal thickness and pupil size (aperture) were used to trace a bundle of rays through the cornea and derive the best focus plane. Corneal power was calculated with respect to the corneal front vertex plane, and the keratometer index was back-calculated using corneal power and front surface radius. Keratometer index was analysed in a multivariate linear model. Results: The averaged resulting keratometer index was 1.3317 ± 0.0017 with a median of 1.3317 and range from 1.3233 to 1.3390. In a univariate model, only the front surface asphericity affected the keratometer index. The multivariate model for modelling the keratometer index using all 6 input parameters performed very well (RMS error: 5.54e-4, R2: 0.90, significance vs. constant model: <0.0001). Conclusions: In the classical calculation, the keratometer index used for converting corneal radius to dioptric power uses several model assumptions. As these assumptions are not generally satisfied, corneal power cannot be calculated from corneal front surface radius alone. Considering all 6 input variables, the linear prediction model performs well and can be used if all input parameters are measured with a tomographer. © 2021 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.
Idézők (9)
Idézett közlemények (5)
Hivatkozás stílusok:
IEEE
ACM
APA
Chicago
Harvard
CSL
Másolás
Nyomtatás
2025-04-14 11:13
×
Lista exportálása irodalomjegyzékként
Hivatkozás stílusok:
IEEE
ACM
APA
Chicago
Harvard
Nyomtatás
Másolás