Comparison between Micro-Computed Tomography and Cone-Beam Computed Tomography in the Assessment of Bone Quality and a Long-Term Volumetric Study of the Augmented Sinus Grafted with an Albumin Impregnated Allograft

Kivovics, Márton ✉ [Kivovics, Márton (fogorvostudomány), szerző] Fogászati és Szájsebészeti Oktató Intézet (SE / FOK); Szabó, Bence Tamás [Szabó, Bence Tamás (Fogászati radiológia), szerző] Orális Diagnosztikai Tanszék (SE / FOK); Németh, Orsolya [Németh, Orsolya (Fogpótlástan), szerző] Fogászati és Szájsebészeti Oktató Intézet (SE / FOK); Iványi, Dóra [Iványi, Dóra (Szájsebészet), szerző] Fogászati és Szájsebészeti Oktató Intézet (SE / FOK); Trimmel, Bálint [Trimmel, Bálint (orális diagnosztika), szerző] Orális Diagnosztikai Tanszék (SE / FOK); Szmirnova, Ilona [Szmirnova, Ilona (Dentoalveolaris s...), szerző] Arc- Állcsont- Szájsebészeti és Fogászati Klinika (SE / FOK); Orhan, Kaan; Mijiritsky, Eitan [Mijiritsky, Eitan (dentistry), szerző]; Szabó, György [Szabó, György (Maxillo facialis ...), szerző] Arc- Állcsont- Szájsebészeti és Fogászati Klinika (SE / FOK); Dobó-Nagy, Csaba [Dobó-Nagy, Csaba (Fogászati radiológia), szerző] Orális Diagnosztikai Tanszék (SE / FOK)

Angol nyelvű Szakcikk (Folyóiratcikk) Tudományos
Megjelent: JOURNAL OF CLINICAL MEDICINE 2077-0383 9 (2) Paper: 303 , 14 p. 2020
    Azonosítók
    Szakterületek:
    • Klinikai orvostan
    The purpose of our study was to compare micromorphometric data obtained by cone-beam computed-tomography (CBCT) and microcomputed-tomography (micro-CT) of the augmented sinus and to evaluate the long-term stability of the bone gain achieved using BoneAlbumin. Sinus lifts, and after 6-months, healing bone-biopsy and implant placement were carried out. Specimens were analyzed by micro-CT. A total of 16 samples were collected from nine patients (mean age 54.7 ± 6.5 years). Pre-, postoperative, and 3-year control CBCT-data were registered to determine from where the biopsy samples were harvested. Micromorphometric variables were calculated from the micro-CT- and CBCT-data, and their correlation was determined by Spearman's test. The volume of augmented bone was calculated at the time of implant placement and after 3 years. A positive correlation was found between bone-volume fraction, trabecular-separation, open-, and total-porosity, while a negative correlation was found between trabecular-thickness obtained from CBCT- and micro-CT-data (p < 0.05). Mean volumetric reduction of 39.28% (11.88–60.02%) was observed. Correlation of CBCT- and micro-CT-data suggested that micromorphometric analysis of CBCT reconstructions of the augmented sinuses provided reliable information on the microarchitecture of augmented bone. CBCT as a modality might be adequate in the analysis of bone quality in the augmented sinus. At the 3-year, control sinus grafts showed volumetric stability.
    Hivatkozás stílusok: IEEEACMAPAChicagoHarvardCSLMásolásNyomtatás
    2025-03-30 05:21