{ "labelLang" : "hun", "responseDate" : "2024-03-29 13:08", "content" : { "otype" : "JournalArticle", "mtid" : 26947330, "status" : "APPROVED", "published" : true, "unhandledTickets" : 0, "oldTimestamp" : "2017-10-31T12:46:42.000+0000", "deleted" : false, "oldId" : 16947330, "lastRefresh" : "2021-09-29T16:05:32.921+0000", "lastModified" : "2017-10-31T12:46:42.000+0000", "created" : "2017-10-31T12:46:08.000+0000", "creator" : { "otype" : "Admin", "mtid" : 10018804, "link" : "/api/admin/10018804", "label" : "Siki Ágnes (SE_FOK_Admin5_SIKIÁ, admin)", "familyName" : "Siki", "givenName" : "Ágnes", "published" : true, "oldId" : 10018804, "snippet" : true }, "lastDuplumOK" : "2019-02-10T22:35:45.947+0000", "lastDuplumSearch" : "2019-02-10T22:35:45.947+0000", "core" : false, "citation" : true, "publicationPending" : false, "type" : { "otype" : "PublicationType", "mtid" : 24, "link" : "/api/publicationtype/24", "label" : "Folyóiratcikk", "code" : 24, "otypeName" : "JournalArticle", "listPosition" : 1, "published" : true, "oldId" : 24, "snippet" : true }, "subType" : { "otype" : "SubType", "mtid" : 10000059, "link" : "/api/subtype/10000059", "label" : "Szakcikk (Folyóiratcikk)", "name" : "Szakcikk", "nameEng" : "Article", "docType" : { "otype" : "PublicationType", "mtid" : 24, "link" : "/api/publicationtype/24", "label" : "Folyóiratcikk", "code" : 24, "otypeName" : "JournalArticle", "listPosition" : 1, "published" : true, "oldId" : 24, "snippet" : true }, "listPosition" : 101, "published" : true, "oldId" : 10000059, "snippet" : true }, "category" : { "otype" : "Category", "mtid" : 1, "link" : "/api/category/1", "label" : "Tudományos", "published" : true, "oldId" : 1, "snippet" : true }, "languages" : [ { "otype" : "Language", "mtid" : 10002, "link" : "/api/language/10002", "label" : "Angol", "name" : "Angol", "nameEng" : "English", "published" : true, "oldId" : 2, "snippet" : true } ], "firstAuthor" : "Bousleiman, H", "authorships" : [ { "otype" : "PersonAuthorship", "mtid" : 73278544, "link" : "/api/authorship/73278544", "label" : "Bousleiman, H", "listPosition" : 1, "share" : 0.0, "first" : true, "last" : false, "familyName" : "Bousleiman", "givenName" : "H", "authorTyped" : true, "editorTyped" : false, "otherTyped" : false, "type" : { "otype" : "AuthorshipType", "mtid" : 1, "link" : "/api/authorshiptype/1", "label" : "Szerző", "code" : 0, "published" : true, "oldId" : 0, "snippet" : true }, "published" : false, "oldId" : 148955208, "snippet" : true }, { "otype" : "PersonAuthorship", "mtid" : 73278545, "link" : "/api/authorship/73278545", "label" : "Iizuka, T", "listPosition" : 2, "share" : 0.0, "first" : false, "last" : false, "familyName" : "Iizuka", "givenName" : "T", "authorTyped" : true, "editorTyped" : false, "otherTyped" : false, "type" : { "otype" : "AuthorshipType", "mtid" : 1, "link" : "/api/authorshiptype/1", "label" : "Szerző", "code" : 0, "published" : true, "oldId" : 0, "snippet" : true }, "published" : false, "oldId" : 148955207, "snippet" : true }, { "otype" : "PersonAuthorship", "mtid" : 73278546, "link" : "/api/authorship/73278546", "label" : "Nolte, L-P", "listPosition" : 3, "share" : 0.0, "first" : false, "last" : false, "familyName" : "Nolte", "givenName" : "L-P", "authorTyped" : true, "editorTyped" : false, "otherTyped" : false, "type" : { "otype" : "AuthorshipType", "mtid" : 1, "link" : "/api/authorshiptype/1", "label" : "Szerző", "code" : 0, "published" : true, "oldId" : 0, "snippet" : true }, "published" : false, "oldId" : 148955206, "snippet" : true }, { "otype" : "PersonAuthorship", "mtid" : 73278547, "link" : "/api/authorship/73278547", "label" : "Reyes, M", "listPosition" : 4, "share" : 0.0, "first" : false, "last" : true, "familyName" : "Reyes", "givenName" : "M", "authorTyped" : true, "editorTyped" : false, "otherTyped" : false, "type" : { "otype" : "AuthorshipType", "mtid" : 1, "link" : "/api/authorshiptype/1", "label" : "Szerző", "code" : 0, "published" : true, "oldId" : 0, "snippet" : true }, "published" : false, "oldId" : 148955205, "snippet" : true } ], "title" : "Population-based design of mandibular fixation plates with bone quality and morphology considerations", "identifiers" : [ { "otype" : "PublicationIdentifier", "mtid" : 13190483, "link" : "/api/publicationidentifier/13190483", "label" : "DOI: 10.1007/s10439-012-0671-8", "source" : { "otype" : "PlainSource", "mtid" : 6, "link" : "/api/publicationsource/6", "label" : "DOI", "type" : { "otype" : "PublicationSourceType", "mtid" : 10001, "link" : "/api/publicationsourcetype/10001", "label" : "DOI", "mayHaveOa" : true, "published" : true, "snippet" : true }, "name" : "DOI", "nameEng" : "DOI", "linkPattern" : "https://doi.org/@@@", "publiclyVisible" : true, "published" : true, "oldId" : 6, "snippet" : true }, "validState" : "NO", "idValue" : "10.1007/s10439-012-0671-8", "realUrl" : "https://doi.org/10.1007%2Fs10439-012-0671-8", "published" : false, "oldId" : 15956121, "snippet" : true }, { "otype" : "PublicationIdentifier", "mtid" : 13190482, "link" : "/api/publicationidentifier/13190482", "label" : "Scopus: 84878505753", "source" : { "otype" : "PlainSource", "mtid" : 3, "link" : "/api/publicationsource/3", "label" : "Scopus", "type" : { "otype" : "PublicationSourceType", "mtid" : 10003, "link" : "/api/publicationsourcetype/10003", "label" : "Indexelő adatbázis", "mayHaveOa" : false, "published" : true, "snippet" : true }, "name" : "Scopus", "linkPattern" : "http://www.scopus.com/record/display.url?origin=inward&eid=2-s2.0-@@@", "publiclyVisible" : true, "published" : true, "oldId" : 3, "snippet" : true }, "validState" : "NO", "idValue" : "84878505753", "realUrl" : "http://www.scopus.com/record/display.url?origin=inward&eid=2-s2.0-84878505753", "published" : false, "oldId" : 15956120, "snippet" : true } ], "journal" : { "otype" : "Journal", "mtid" : 328, "link" : "/api/journal/328", "label" : "ANNALS OF BIOMEDICAL ENGINEERING 0090-6964", "pIssn" : "0090-6964", "reviewType" : "REVIEWED", "noIF" : false, "sciIndexed" : true, "scopusIndexed" : true, "lang" : "FOREIGN", "hungarian" : false, "published" : true, "oldId" : 328, "snippet" : true }, "volume" : "41", "issue" : "2", "firstPage" : "377", "lastPage" : "384", "firstPageOrInternalIdForSort" : "377", "pageLength" : 8, "publishedYear" : 2013, "digital" : null, "printed" : null, "sourceYear" : 2017, "packet" : "(Siki Ágnes (SE_FOK_Adm5_SIKIÁ); 2017.10.31. 13:46:03)", "foreignEdition" : true, "foreignLanguage" : true, "fullPublication" : true, "conferencePublication" : false, "nationalOrigin" : null, "missingAuthor" : false, "oaType" : "NONE", "oaCheckDate" : "2021-09-29", "oaFree" : false, "citationCount" : 0, "citationCountUnpublished" : 0, "citationCountWoOther" : 0, "independentCitCountWoOther" : 0, "doiCitationCount" : 0, "wosCitationCount" : 0, "scopusCitationCount" : 0, "independentCitationCount" : 0, "unhandledCitationCount" : 0, "citingPubCount" : 0, "independentCitingPubCount" : 0, "unhandledCitingPubCount" : 0, "citedPubCount" : 1, "citedCount" : 1, "ratings" : [ { "otype" : "SjrRating", "mtid" : 11118606, "link" : "/api/sjrrating/11118606", "label" : "sjr:Q1 (2013) Scopus - Biomedical Engineering ANNALS OF BIOMEDICAL ENGINEERING 0090-6964", "listPos" : 35, "rankValue" : 0.24, "type" : "journal", "ratingType" : { "otype" : "RatingType", "mtid" : 10002, "link" : "/api/ratingtype/10002", "label" : "sjr", "code" : "sjr", "published" : true, "snippet" : true }, "subject" : { "otype" : "ClassificationExternal", "mtid" : 2204, "link" : "/api/classificationexternal/2204", "label" : "Scopus - Biomedical Engineering", "published" : true, "oldId" : 2204, "snippet" : true }, "ranking" : "Q1", "calculation" : "DIRECT", "published" : true, "snippet" : true } ], "ratingsForSort" : "Q1", "referenceList" : "Bousleiman, H., Seiler, C., Iizuka, T., Nolte, L.-P., Reyes, M., Population-based design of mandibular plates based on bone quality and morphology (2012) Proceedings of 15th International Conference on Medical Image Computing and Computer-Assisted Intervention MICCAI, (PART I), pp. 6-73; \n\nBou-Sleiman, H., Ritacco, L.E., Nolte, L.-P., Reyes, M., Minimization of intra-operative shaping of orthopaedic fixation plates: A population-based design (2011) Proceedings of 14th International Conference on Medical Image Computing and Computer-Assisted Intervention MICCAI, (PART II), pp. 409-416; \n\nFrankle, M.A., Cordey, J., Frankle, M.D., Baumgart, F., Perren, S., A retrospective analysis of plate contouring in the tibia using the conventional 4.5 (narrow) dynamic compression plate (1994) J. Orthop. Trauma, 8, pp. 59-63. , 8169697 10.1097/00005131-199402000-00013 1:STN:280:DyaK2c3itleqtw%3D%3D; \n\nFranklin, D., O'Higgins, P., Oxnard, C.E., Dadour, I., Sexual dimorphism and population variation in the adult mandible forensic applications of geometric morphometrics (2007) Forensic Sci. Med. Pathol., 3, pp. 15-22; \n\nGoyal, K.S., Skalak, A.S., Marcus, R.E., Vallier, H.A., Cooperman, D.R., Analysis of anatomic periarticular tibial plate fit on normal adults (2007) Clin. Orthop. Relat. Res., 461, pp. 245-257. , 17496554; \n\nHong, J., Lim, Y.-J., Park, S.-O., Quantitative biomechanical analysis of the influence of the cortical bone and implant length on primary stability (2011) Clin. Oral Implants Res., 23 (10), pp. 1193-1197. , 22092387 10.1111/j.1600-0501.2011.02285.x; \n\nKozic, N., Weber, S., Büchler, P., Lutz, C., Reimers, N., González, M., Reyes, M., Optimisation of orthopaedic implant design using statistical shape space analysis based on level sets (2010) Med. Image Anal., 14, pp. 265-275. , 20359938 10.1016/j.media.2010.02.008; \n\nLilliefors, H.W., On the Kolmogorov-Smirnov Test for normality with mean and variance unknown (1967) J. Am. Stat. Assoc., 62, pp. 399-402. , 10.1080/01621459.1967.10482916; \n\nMerheb, J., Van Assche, N., Coucke, W., Jacobs, R., Naert, I., Quirynen, M., Relationship between cortical bone thickness or computerized tomography-derived bone density values and implant stability (2010) Clin. Oral Implants Res., 21, pp. 612-617. , 20666788 10.1111/j.1600-0501.2009.01880.x; \n\nNagamune, K., Kokubo, Y., Baba, H., Computer-assisted designing system for fixation plate (2009) IEEE International Conference on Fuzzy Systems - FUZZ IEEE, pp. 975-980; \n\nOettlé, A.C., Becker, P.J., De Villiers, E., Steyn, M., The influence of age, sex, population group, and dentition on the mandibular angle as measured on a South African sample (2009) Am. J. Phys. Anthropol., 139, pp. 505-511. , 19235793 10.1002/ajpa.21009; \n\nPerren, S.M., Evolution and rationale of locked internal fixator technology. Introductory remarks (2001) Injury, 32 (SUPPL. 2), pp. 3-B9. , 11718733 10.1016/S0020-1383(01)00120-6; \n\nPetrie, A., Statistics in orthopaedic papers (2006) J. Bone Joint Surg. Br., 88, pp. 1121-1136. , 16943459 10.1302/0301-620X.88B9.17896 1:STN:280:DC%2BD28rhvFKltA%3D%3D; \n\nPonyi, S., Szabó, G., Statistical investigation of mandibular dimensions for the planning of a series of mandibular corpus replacements (1990) J. Craniofac. Surg., 2, pp. 1049-2275; \n\nSchiuma, D., Brianza, S., Tami, A.E., Development of a novel method for surgical implant design optimization through noninvasive assessment of local bone properties (2011) Med. Eng. Phys., 33, pp. 256-262. , 20980189 10.1016/j.medengphy.2010.09.024 1:STN:280:DC%2BC3M3htlOhug%3D%3D; \n\nSchmutz, B., Wullschleger, M.E., Noser, H., Barry, M., Meek, J., Schutz, M.A., Fit optimisation of a distal medial tibia plate (2011) Comput. Methods Biomech. Biomed. Eng., 14, pp. 359-364. , 10.1080/10255842.2010.482044; \n\nSeiler, C., Pennec, X., Reyes, M., Geometry-aware multiscale image registration via OBBTree-based polyaffine log-demons (2011) Proceedings of 14th International Conference on Medical Image Computing and Computer-Assisted Intervention MICCAI, (PART II), pp. 631-638; \n\nTaljanovic, M.S., Jones, M.D., Ruth, J.T., Benjamin, J.B., Sheppard, J.E., Hunter, T.B., Fracture fixation (2003) Radiographics, 23, pp. 1569-1590. , 14615566 10.1148/rg.236035159; \n\nWagner, M., General principles for the clinical use of the LCP (2003) Injury, 34 (SUPPL. 2), pp. 31-B42. , 14580984 10.1016/j.injury.2003.09.023; \n\nZhang, J., Yan, C.-H., Chui, C.-K., Ong, S.H., Accurate measurement of bone mineral density using clinical CT imaging with single energy beam spectral intensity correction (2010) IEEE Trans. Med. Imaging, 29, pp. 1382-1389. , 20236874 10.1109/TMI.2010.2045767 1:CAS:528:DC%2BC3cXhtlyiu77J", "hasCitationDuplums" : false, "userChangeableUntil" : "2018-01-29T12:46:42.000+0000", "publishDate" : "2017-10-31T12:46:42.000+0000", "directInstitutesForSort" : "", "ownerAuthorCount" : 1, "ownerInstituteCount" : 3, "directInstituteCount" : 0, "authorCount" : 4, "contributorCount" : 0, "hasQualityFactor" : true, "link" : "/api/publication/26947330", "label" : "Bousleiman H et al. Population-based design of mandibular fixation plates with bone quality and morphology considerations. (2013) ANNALS OF BIOMEDICAL ENGINEERING 0090-6964 41 2 377-384", "template" : "